Availability: | |
---|---|
BMS HS-10S66A-1300W
Helithtech
Product Description
With the wide application of iron-lithium batteries in the communication industry, requirements for high performance, high reliability, and high cost performance have also been put forward for battery management systems. This product is a BMS specially designed for base station backup batteries. It adopts an integrated design and integrates collection, management, communication and other functions into one. It can be widely used in indoor and outdoor base stations, such as integrated base stations, edge stations, repeaters, macro base stations, solar base stations, etc.
Functional Features
Highly Integrated Analogue Front End
Isolated Power Supply Circuit
Integrated Serial Port IC
High Voltage Accuracy (≤10mV)
High Current Accuracy (≤2%@FS)
4-Way Battery Temperature Detection (≤2°C)
SOC Estimation Function
SOH Estimation Function
Short Circuit Protection Function
Adjustable Over-Current Protection
Multiple Sleep And Wake-Up Modes
Low Power Consumption
RS485 Communication
Adjustable Parameter Settings
Data Refresh Interval (Period) ≤ 2 Seconds
LED Status Indication Function
Charge Equalization Function
SOC Accuracy (≤5% @ 50% Capacity Range Or More)
Functional Block Diagram
Parameters
No. | Indicator Items | Factory Default Parameters | Is It Possible To Set | Remark | |
1 | Monomer Overcharge Protection | Monomer Overcharge Alarm Voltage | 3600mV | Settable | monomer overcharge protection value is inconsistent with mobile default value |
Monomer Overcharge Protection Voltage | 3650mV | Settable | |||
Monomer Overcharge Protection Delay | 1.0S | Settable | |||
Monomer Overvoltage Protection Disengaged | Release Voltage of Monomer Over-Discharge Protection | 3380mV | Settable | ||
Capacity Release | SOC≤94% | Settable | |||
Discharge Release | discharge current > 1A | ||||
2 | Monomer Over-Discharge Protection | Monomer Over-Discharge Warning Voltage | 2700mV | Settable | |
Monomer Over-Discharge Protection Voltage | 2500mV | Settable | after 30 seconds of over-discharge protection, if it cannot be recovered, it will enter low power mode | ||
Monomer Over-Discharge Protection Delay | 1.0S | Settable | |||
Monomer Over-Discharge Protection Disengaged | Release Voltage of Monomer Over-Discharge Protection | 2750mV | Settable | ||
Release When Charging | activated by connecting to the charger | ||||
3 | Total Overcharge Protection | Total Overcharge Warning Voltage | 57.6V | Settable | |
Total Overcharge Protection Voltage | 58.4V | Settable | |||
Total Overcharge Protection Delay | 1.0S | Settable | |||
Total Overvoltage Protection Disengaged | Release Voltage of Total Overcharge Protection | 54V | Settable | ||
Capacity Release | SOC≤94% | Settable | |||
Discharge Release | discharge current > 1A | ||||
4 | Total Over-Discharge Protection | Total Over-Discharge Warning Voltage | 43.2V | Settable | after 30 seconds of over-discharge protection, if it cannot be recovered, it will enter low power mode |
Total Over-Discharge Protection Voltage | 40V | Settable | |||
Total Over-Discharge Protection Delay | 1.0S | Settable | |||
Total Over-Discharge Protection Disengaged | Release Voltage of Total Over-Discharge Protection | 44V | Settable | ||
Release When Charging | activated by connecting to the charger | ||||
5 | Charging Overcurrent Protection | Charging Overcurrent Warning Current | 75A | Settable | the state will be locked after 3 consecutive occurrences and will not be automatically unlocked. |
Charging Overcurrent Protection Current | 80A | Settable | |||
Charging Overcurrent Protection Delay | 1.0S | Settable | |||
Charging Overcurrent Protection Disengaged | Automatic Release | Automatic release after 2min | |||
Discharge Release | discharge current > 1A | ||||
6 | Discharging Overcurrent 1 Protection | Alarm Current of Discharging Overcurrent 1 Idm | 160A | Settable | the state will be locked after 3 consecutive occurrences and will not be automatically unlocked. |
Protection Current of Discharging Overcurrent 1 | 170A | Settable | |||
Protection Delay of Discharging Overcurrent 1 | 1.0S | Settable | |||
Discharging Overcurrent 1 Protection Disengaged | Automatic Release | Automatic release after 2min | |||
Charge Release | Charging current > 1A | ||||
7 | Discharge Overcurrent 2 | Protection Current of Discharging Overcurrent 2 | ≥180A | Settable | the state will be locked after 1 occurrence and will not be automatically unlocked. |
Protection Delay of Discharging Overcurrent 2 | 100mS | Settable | |||
Discharge Overcurrent 2 Protection Disengaged | Automatic Release | Automatic release after 2min | |||
Charge Release | Charging current > 1A | ||||
8 | Short Circuit Protection | Short Circuit Protection | Yes | ||
Short Circuit Protection Disengaged | Short-circuit protection will be disengaged when charging | ||||
Short-circuit protection will be automatically lifted when the load is removed. | |||||
9 | MOS High Temperature Protection | Temperature Value of MOS High Temperature Warning | 90℃ | Settable | |
Temperature Value of MOS High Temperature Protection | 110℃ | Settable | |||
Release Temperature of MOS Protection | 90℃ | Settable | |||
10 | Cell Temperature Protection | Temperature Value of Charging Low Temperature Warning | 3℃ | Settable | |
Temperature Value of Charging Low Temperature Protection | 0℃ | Settable | |||
Release Temperature of Charging Low Temperature Protection | 3℃ | Settable | |||
Temperature Value of Charging High Temperature Warning | 55℃ | Settable | |||
Temperature Value of Charging High Temperature Protection | 60℃ | Settable | |||
Release Temperature of Charging High Temperature Protection | 55℃ | Settable | |||
Temperature Value of Discharge Low Temperature Warning | -10℃ | Settable | |||
Temperature Value of Discharge low temperature protection | -20℃ | Settable | |||
Release Temperature of Discharge Low Temperature Protection | 0℃ | Settable | |||
Temperature Value of Discharge High Temperature Warning | 55℃ | Settable | |||
Temperature Value of Discharge High Temperature Protection | 60℃ | Settable | |||
Release Temperature of Discharge High Temperature Protection | 50℃ | Settable | |||
11 | Ambient Temperature Alarms | Temperature Value of Ambient Low Temperature Warning | -10℃ | Settable | |
Temperature Value of Ambient Low Temperature Protection | -20℃ | Settable | |||
Release Temperature of Ambient Low Temperature Protection | 0℃ | Settable | |||
Temperature Value of Ambient High Temperature Warning | 60℃ | Settable | |||
Temperature Value of Ambient High Temperature Protection | 65℃ | Settable | |||
Release Temperature of Ambient High Temperature Protection | 55℃ | Settable | |||
12 | Current Consumption | Self-Consumption Current During Operation | ≤25mA | ||
Light Hibernation Current | ≤200μA | ||||
13 | Equalization Function | The Voltage When The Equalization Function is Turned On | 3400mV | Settable | Equalization should not be activated when the voltage difference between the cells is greater than 1V |
The Differential Pressure When The Equalization Function is Turned On | 30mV | Settable | |||
14 | Capacity Default Setting | Low Battery Alarm | SOC<20% | Settable | No alarms when charging. |
15 | Hibernation Function | Sleeping Voltage | 2500mV | Settable | |
Delay Time | 1h | Settable | |||
16 | Cell Failure Protection | Monomer Differential Pressure | Voltage difference>800mV | Settable( 300mV-800mV) | No charging or discharging allowed |
17 | Full Charge Judgement | Full Charge Voltage | 57.6V | ||
Cut-off Current | 2A |