pro-banner
PRODUCT DETAIL
You are here: Home » Products » Home Storage Battery » Rack Mounted Battery » 60.8V 16Ah Rack Type LiFePO4 Battery

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

60.8V 16Ah Rack Type LiFePO4 Battery

The 60.8V 16Ah rack-mounted lithium iron phosphate battery is a type of battery commonly used for energy storage and power supply applications. It utilizes lithium iron phosphate as the positive electrode material, known for its safety and stability. With a rated voltage of 60.8V, the battery can provide a voltage output of 60.8 volts when fully charged. Its capacity is rated at 16 ampere-hours (Ah), indicating its ability to deliver a current of 16 amps for one hour. This type of battery finds its use in various settings, including energy storage systems, uninterruptible power supply (UPS) systems, and solar energy storage systems, due to its stability, longevity, and higher safety compared to other lithium-ion chemistries.
Availability:
  • 60.8V 16Ah LiFePO4 Battery Pack

  • Helithtech

Technical Specifications

#

Item

Parameter

Remark

1

Shell Material

Aluminum Alloy


2

Cell Chemical System

LiFePO4

lithium iron phosphate

3

Nominal Capacity

100Ah

Discharge 0.5C and 2.5V cut off (25±2)℃

4

Delivery Capacity

>100Ah

1.0C discharge

5

Typical Voltage

3.2V

working voltage

6

Max Charge Voltage

3.65V


7

Standard Charge Rate

0.5C

0.5C CC, 3.65V CV to 3.65V, cut off when charging rate lower than 0.05C

8

Standard Discharging Rate

0.5C


9

Max. Discharging Current

1C


10

Max. Pulse Discharging Current

2C

30s

11

Internal Impedance

≤0.8mΩ

1kHz, 2% SOC

12

Operation Conditions

Charge

0℃~50℃, 60±25%R.H.

Low temperature charging like below 0℃ gets lower capacity and reduces cycle life.

Discharge

-20℃~60℃, 60±25%R.H.

13

Storage Conditions

-20℃~55℃, 60±25%R.H.

Cell must be recharged per half year, while battery packs with BMS per three months.

14

Net Weight

2.03Kg

±30g


BMS Specifications

#

Function

Description

Specification

Remark

1

Cell Over Voltage

Protection

Alarm Voltage

3600mV

settable

Protection Voltage

3650mV

settable

Protection Delay

1.0s

settable

Cell Over

Voltage Protection Release

Voltage Release

3340mV

settable

Capacity Release

SOC<96%

settable

Discharge Current Release

1A


2

Cell Low Voltage

Protection

Alarm Voltage

3000mV

settable

Protection Voltage

2700mV

settable

Protection Delay

1.0s

settable

Cell Low Voltage Protection Release

Voltage Release

3100mV

settable

Charge Release

Automatic Release after Charging


3

Pack Over Voltage

Protection

Alarm Voltage

54V

settable

Protection Voltage

54.75V

settable

Protection Delay

1.0s

settable

Pack Over

Voltage Protection Release

Voltage Release

51V

settable

Capacity Release

SOC<96%

settable

Discharge Current Release

1A


4

Pack Low Voltage

Protection

Alarm Voltage

48V

settable

Protection Voltage

40.5V

settable

Protection Delay

1.0s

settable

Pack Low Voltage Protection Release

Voltage Release

46.5V

settable

Charge Release

Automatic Release after Charging


5

Pack Charge Over Current

Protection

Alarm Current

200A

settable

Protection Current

210A

settable

Protection Delay

1.0s

settable

Pack Charge Over Current Protection Release

Automatic Release

1 minute after charger disconnection

Discharge Current Release

> 1A


6

Discharge Over

Current Protection Level 1

Protection Current

210A

settable

Protection Delay

1.0s

settable

Discharge Over

Current Protection Level 1 Release

Automatic Release

1 minute after charger disconnection

Discharge Current Release

> 1A


7

Discharge Over

Current Protection Level 2

Protection Current

240A

settable

Protection Delay

100ms

settable

Discharge Over

Current Protection Level 2 Release

Automatic Release

1 minute after charger disconnection

Discharge Current Release

> 1A


8

Short Circuit Protection

Short Circuit Prediction

Short circuit of external load


Protection Current

Three to four times of continuous discharge current

Protection Delay

< 3s


Short Circuit Protection Release

Charge Release

Automatic Release after Charging


Load Disconnection

External Load removed


9

MOSFET High Temperature Protection

Alarm Temperature

110℃

settable

Protection Temperature

115℃

settable

Protection Release

95℃

settable

10

Charge Low Temperature Protection

Low Temperature Alarm

5℃

settable

Protection Temperature

0℃

settable

Protection Release Temperature

5℃

settable

11

Charge High Temperature Protection

High Temperature Alarm

55℃

settable

Protection Temperature

60℃

settable

Protection Release Temperature

55℃

settable

12

Discharge Low Temperature Protection

Low Temperature Alarm

-15℃

settable

Protection Temperature

-20℃

settable

Protection Release Temperature

-10℃

settable

13

Discharge High Temperature Protection

High Temperature Alarm

60℃

settable

Protection Temperature

65℃

settable

Protection Release Temperature

60℃

settable

14

Low Ambient Temperature Protection

Low Temperature Alarm

-20℃

settable

Protection Temperature

-25℃

settable

Protection Release Temperature

-20℃

settable

15

High Ambient Temperature Protection

High Temperature Alarm

60℃

settable

Protection Temperature

65℃

settable

Protection Release Temperature

60℃

settable

16

Balance Function

Activation Voltage

3380mV

settable

Activation Voltage Difference

30mV

settable

17

Self-Consumption

Working Current

With LCD

≤ 40mA


Without LCD

≤ 30mA


Low Power Mode

≤ 250uA


18

SOC Default

Setting

Low Capacity Alarm

< 5%

settable

Low Capacity Alarm Release

≥ 20%

settable

Full Capacity Setting

200Ah

settable

19

Dormancy Function

Dormancy Voltage

3300mV / Cell

settable

Dormancy Delay

5 minutes

settable


Battery Pack Specifications

#

Items

Characteristics

Remark

1

Capacity

Normal Capacity

200Ah

5120Wh, 0.33C, 25℃

Minimum

97%

0.5C, 25℃

2

Voltage

Nominal Voltage

48V

3.2V per cell

Normal Charge Voltage

54.75V

3.65V per cell

Float Charge (for Standby Use)

55.75V±0.5V

3.45V per cell

End of Discharge

37.5V

2.5V per cell

3

Charge

Maximum Charge Current

200A

1C

Suggested Charge Current

≤40A

0.2C

Charging Current Limit

40A


4

Discharge

Maximum Discharge Current

200A

1C

Suggested Discharge Current

≤40A

0.2C

Inverter Connection

YES

capacitive load ≤ 27000μF

5

Indicator

SOC (state of charge)

Green LED x5

see Product External for details

RUN

Green LED x1

ALARM

Red LED x1

6

Environment

Operation Temperature

Charge

0~45℃


Discharge

-10℃~65℃


Storage Temperature

-20℃~50℃


Relative Humidity

5%~95%


Altitude

<3600m


7

Communication

Port

RS232/RS485/CAN

RJ45 x2 & RJ11 x1

Protocol

Modbus

customizable

Dry Contact

Yes

customizable

Dial Switch

4 bit binary


8

General

Shell Material

Q235

SPCC

Physical Protection Level

IP30


Dimensions

W482xH220xD550

±2mm

Net Weight

75Kg

±1Kg


Precautions

Precautions

  1. Installation Guidelines: Ensure proper installation of the 60.8V 16Ah rack-mounted lithium iron phosphate battery according to manufacturer guidelines. Follow wiring and connection instructions to prevent damage or safety hazards.

  2. Temperature Management: Maintain the recommended operating temperature range for the battery. Extreme temperatures can affect performance and lifespan. Provide proper ventilation if necessary.

  3. Charging Parameters: Use a compatible charger with appropriate voltage and current settings for the battery. Avoid overcharging or charging at too high a rate, as it could lead to reduced battery life or safety risks.

  4. Discharge Rate: Avoid discharging the battery at a rate exceeding its specifications. Excessive discharge rates can cause voltage drops, heat buildup, and potential damage.

  5. Monitoring and Management: Implement a battery management system (BMS) to monitor cell voltage, temperature, and overall health. Regularly check the BMS alerts and alarms.

  6. Compatibility: Ensure the battery is compatible with your application's voltage and power requirements. Mismatched voltage or capacity could lead to inefficiencies or malfunctions.

  7. Transport and Handling: When transporting the battery, follow transportation regulations for lithium batteries. Handle the battery with care to prevent physical damage.

  8. Storage Conditions: If storing the battery for an extended period, store it at a partial charge in a cool, dry environment. Check the manufacturer's recommendations for optimal storage conditions.

  9. Maintenance: Regularly inspect the battery for signs of damage, leakage, or abnormal behavior. Perform recommended maintenance procedures according to the manufacturer's guidelines.

  10. Recycling: When the battery reaches the end of its life cycle, follow proper recycling procedures for lithium batteries. Improper disposal can have negative environmental impacts.

Remember that these are general precautions. Always refer to the manufacturer's specific guidelines and recommendations for the 60.8V 16Ah rack-mounted lithium iron phosphate battery you are using to ensure safe and proper operation.

Previous: 
Next: 

ABOUT HELITH

Battery Based Energy System Integration Expert
A new energy system integration company invested by Great Power's fund and a number of technical experts in different fields.
Our company offer lithium battery based energy storage solution and battery pack to cusotmer all over the world.With experienced technical engineers, Helith truns idea to product mass production.
 
Contact Us
CONTACT US

About

Products

Solution

Support

Copyright © 2022 Helith Technology (Guangzhou) Co., Ltd. All Rights Reserved.   Support by Leadong