51.2V 40AH 2P16S Battery Module

The battery module is a configuration of 2 sets of 16 series-connected battery cells in parallel, resulting in a total voltage of 51.2V and a capacity of 40 ampere-hours (Ah). This setup is commonly used in applications such as electric vehicles, energy storage systems, and solar power storage. It requires a Battery Management System (BMS) to monitor and balance the cells, ensuring safe and efficient operation.
Availability:
  • 51.2V40AH-2P16S

  • Helithtech

Product Description

General Information


  • Voltage: 51.2V

  • Capacity: 40 ampere-hours (Ah)

  • Configuration: 2 sets of 16 series-connected cells in parallel (2P16S)

This configuration is commonly used in applications like electric vehicles, energy storage systems, and solar power storage, and it necessitates a Battery Management System (BMS) for monitoring and maintaining safe operation.

Battery module parameter

No.parameterproduct specificationcondition
1serial parallel mode2P16S/
2voltage capacity51.2V/40Ah/
3length /mm349± 1.5/
4width /mm204.3± 1.0/
5high /mm206.9± 1.0/
6weight /kg13.6±1.0/



No.projectSpecificationRemark
1electrical propertiesNominal voltage /V51.2/
2Charge cut-off voltage /V58.4/
3Discharge cut-off voltage /V40T > 0 ℃
432T ≤ 0 ℃
5Nominal capacity /Ah400.5C , 25℃±2℃
6AC internal resistance /mΩ< 3m Ω1000Hz down measurement
7Standard charging current /A20/
8Standard discharge current /A20/
9Maximum Continuous Charge Current /A30/
10Maximum Continuous Discharge Current /A72
11Maximum pulse discharge current /A144last 5 S , SOC≥20%
12Charging working temperature /°C0 ~50
13Discharge working temperature /°C-20 ~55
14storage temperature /°C-20 ~45/
15storage humidity≤85%/
16cycle life≥3000 Second-rate (70% Rated Capacity )Standard charge and discharge, 25 ± 2 ℃
17safety performanceOverdischarge, short circuit, extrusion, dropno fire, no disintegration/
18Depression, thermal shock, sea immersion Bubbles, high temperature and high humidityno fire, no disintegration/
19charging terminal3.65V Dynamic differential pressure /mV500/
203.5V Dynamic differential pressure /mV300/
2130 Static pressure difference after minutes /mV8/
22discharge end2.6V Dynamic differential pressure /mV300/
232.7V Dynamic differential pressure /mV200/
2430 Static pressure difference after minutes /mV10/
25to shipmodule SOC50%/




Precautions

Precautions


When using the battery module, it's important to keep the following precautions in mind:

  1. Proper Handling: Handle the battery module with care to avoid physical damage or punctures that could lead to safety hazards.

  2. Charging: Only use chargers recommended by the manufacturer to prevent overcharging, which can damage the cells and pose safety risks.

  3. Discharging: Avoid deep discharges, as they can reduce the overall lifespan of the battery. Use within the specified voltage range.

  4. Temperature: Operate the battery within the recommended temperature range. Extreme heat or cold can impact performance and safety.

  5. Ventilation: Provide adequate ventilation when charging or discharging to prevent excessive heat buildup.

  6. Battery Management System (BMS): Ensure the BMS is functioning properly to monitor cell balance, temperature, and prevent overcharging or over-discharging.

  7. Physical Protection: Protect the battery from physical impacts, moisture, and exposure to flammable materials.

  8. Storage: If storing the battery for an extended period, ensure it's at a partial charge (around 50%) and in a cool, dry place.

  9. Compatibility: Use the battery module in systems designed to handle its specifications to prevent overloading or other compatibility issues.

  10. Maintenance: Regularly inspect and maintain connections, wiring, and the BMS to ensure safe and reliable operation.

  11. Authorized Service: Seek professional assistance from authorized technicians for any maintenance, repair, or modification.

Always refer to the manufacturer's guidelines and documentation for specific usage instructions and safety recommendations.


Previous: 
Next: 

ABOUT HELITH

Battery Based Energy System Integration Expert
A new energy system integration company invested by Great Power's fund and a number of technical experts in different fields.
Our company offer lithium battery based energy storage solution and battery pack to cusotmer all over the world.With experienced technical engineers, Helith truns idea to product mass production.
 
Contact Us
CONTACT US

About

Products

Solution

Support

Copyright © 2022 Helith Technology (Guangzhou) Co., Ltd. All Rights Reserved.   Support by Leadong