Availability: | |
---|---|
51.2V100AH-1P16S
Helithtech
Product Description
Voltage: 51.2V
Capacity: 100Ah
Configuration: 1P16S (1 series, 16 parallel)
Total Cells: 16
Series Connection: 16 cells in series
Parallel Connection: 1 set of 16 series-connected cells
Application: Suitable for electric vehicles, solar energy storage, UPS, and similar applications.
Please note that the specifications provided are based on the information you've provided. If you need further details or have specific questions, feel free to ask.
Battery module parameter
No. | parameter | product specification | condition | |||||||||||||||||||
1 | serial parallel mode | 1P16S | / | |||||||||||||||||||
2 | voltage capacity | 51.2V/100Ah | / | |||||||||||||||||||
3 | length /mm | 464± 3.0 | / | |||||||||||||||||||
4 | width /mm | 340± 5.0 | / | |||||||||||||||||||
5 | high /mm | 133± 2.0 | / | |||||||||||||||||||
6 | weight /kg | 36±1.5 | / |
No. | project | Specification | Remark | |||||||||||||||||||
1 | electrical properties | Nominal voltage /V | 51.2 | / | ||||||||||||||||||
2 | Charge cut-off voltage /V | 58.4 | / | |||||||||||||||||||
3 | Discharge cut-off voltage /V | 40 | T > 0 ℃ | |||||||||||||||||||
4 | 32 | T ≤ 0 ℃ | ||||||||||||||||||||
5 | Nominal capacity /Ah | 100 | 0.5C , 25℃±2℃ | |||||||||||||||||||
6 | AC internal resistance /mΩ | < 3m Ω | 1000Hz down measurement | |||||||||||||||||||
7 | Standard charging current /A | 50 | / | |||||||||||||||||||
8 | Standard discharge current /A | 50 | / | |||||||||||||||||||
9 | Maximum Continuous Charge Current /A | 100 | / | |||||||||||||||||||
10 | Maximum Continuous Discharge Current /A | 100 | ||||||||||||||||||||
11 | Maximum pulse discharge current /A | 200 | last 5 S , SOC≥20% | |||||||||||||||||||
12 | Charging working temperature /°C | 0 ~50 | ||||||||||||||||||||
13 | Discharge working temperature /°C | -20 ~55 | ||||||||||||||||||||
14 | storage temperature /°C | -20 ~45 | / | |||||||||||||||||||
15 | storage humidity | ≤85% | / | |||||||||||||||||||
16 | cycle life | ≥3000 Second-rate (70% Rated Capacity ) | Standard charge and discharge, 25 ± 2 ℃ | |||||||||||||||||||
17 | safety performance | Overdischarge, short circuit, extrusion, drop | no fire, no disintegration | / | ||||||||||||||||||
18 | Depression, thermal shock, sea immersion Bubbles, high temperature and high humidity | no fire, no disintegration | / | |||||||||||||||||||
19 | charging terminal | 3.65V Dynamic differential pressure /mV | 500 | / | ||||||||||||||||||
20 | 3.5V Dynamic differential pressure /mV | 300 | / | |||||||||||||||||||
21 | 30 Static pressure difference after minutes /mV | 8 | / | |||||||||||||||||||
22 | discharge end | 2.6V Dynamic differential pressure /mV | 300 | / | ||||||||||||||||||
23 | 2.7V Dynamic differential pressure /mV | 200 | / | |||||||||||||||||||
24 | 30 Static pressure difference after minutes /mV | 10 | / | |||||||||||||||||||
25 | to ship | module SOC | 50% | / |
Precautions
Usage Environment: Ensure the battery module is operated within the specified temperature and humidity range to maintain optimal performance and lifespan.
Charging: Use a compatible charger that matches the voltage and charging characteristics of the battery module to prevent overcharging or damage.
Discharging: Avoid excessive discharging to prevent over-discharge, which can damage the battery cells and reduce their lifespan.
Balancing: Regularly balance the cells within the module to ensure uniform charge and discharge across all cells, maximizing overall efficiency.
Maintenance: Periodically inspect for physical damage, leakage, or abnormal behavior. Replace damaged or malfunctioning cells promptly.
Transportation: Follow proper guidelines for transporting the battery module, adhering to safety regulations to prevent accidents or hazards.
Storage: Store the battery module in a cool, dry place at around 50% charge if not in use for extended periods to extend its overall lifespan.
Compatibility: Ensure that the battery module is compatible with the intended application's voltage and capacity requirements.
Safety Precautions: Always use proper safety gear when handling, installing, or maintaining the battery module. Avoid short-circuiting and exposure to high temperatures.
Documentation: Keep the user manual and technical specifications handy for reference and troubleshooting.
Professional Assistance: Seek professional help for installation, maintenance, or any issues beyond your expertise.
Remember that handling battery modules requires careful attention to safety and proper usage to maximize performance and longevity while minimizing potential risks.