Voltage: 51.2V
Capacity: 40 ampere-hours (Ah)
Configuration: 2 sets of 16 series-connected cells in parallel (2P16S)
This configuration is commonly used in applications like electric vehicles, energy storage systems, and solar power storage, and it necessitates a Battery Management System (BMS) for monitoring and maintaining safe operation.
No. | parameter | product specification | condition | |||||||||||||||||||
1 | serial parallel mode | 2P16S | / | |||||||||||||||||||
2 | voltage capacity | 51.2V/40Ah | / | |||||||||||||||||||
3 | length /mm | 349± 1.5 | / | |||||||||||||||||||
4 | width /mm | 204.3± 1.0 | / | |||||||||||||||||||
5 | high /mm | 206.9± 1.0 | / | |||||||||||||||||||
6 | weight /kg | 13.6±1.0 | / |
No. | project | Specification | Remark | |||||||||||||||||||
1 | electrical properties | Nominal voltage /V | 51.2 | / | ||||||||||||||||||
2 | Charge cut-off voltage /V | 58.4 | / | |||||||||||||||||||
3 | Discharge cut-off voltage /V | 40 | T > 0 ℃ | |||||||||||||||||||
4 | 32 | T ≤ 0 ℃ | ||||||||||||||||||||
5 | Nominal capacity /Ah | 40 | 0.5C , 25℃±2℃ | |||||||||||||||||||
6 | AC internal resistance /mΩ | < 3m Ω | 1000Hz down measurement | |||||||||||||||||||
7 | Standard charging current /A | 20 | / | |||||||||||||||||||
8 | Standard discharge current /A | 20 | / | |||||||||||||||||||
9 | Maximum Continuous Charge Current /A | 30 | / | |||||||||||||||||||
10 | Maximum Continuous Discharge Current /A | 72 | ||||||||||||||||||||
11 | Maximum pulse discharge current /A | 144 | last 5 S , SOC≥20% | |||||||||||||||||||
12 | Charging working temperature /°C | 0 ~50 | ||||||||||||||||||||
13 | Discharge working temperature /°C | -20 ~55 | ||||||||||||||||||||
14 | storage temperature /°C | -20 ~45 | / | |||||||||||||||||||
15 | storage humidity | ≤85% | / | |||||||||||||||||||
16 | cycle life | ≥3000 Second-rate (70% Rated Capacity ) | Standard charge and discharge, 25 ± 2 ℃ | |||||||||||||||||||
17 | safety performance | Overdischarge, short circuit, extrusion, drop | no fire, no disintegration | / | ||||||||||||||||||
18 | Depression, thermal shock, sea immersion Bubbles, high temperature and high humidity | no fire, no disintegration | / | |||||||||||||||||||
19 | charging terminal | 3.65V Dynamic differential pressure /mV | 500 | / | ||||||||||||||||||
20 | 3.5V Dynamic differential pressure /mV | 300 | / | |||||||||||||||||||
21 | 30 Static pressure difference after minutes /mV | 8 | / | |||||||||||||||||||
22 | discharge end | 2.6V Dynamic differential pressure /mV | 300 | / | ||||||||||||||||||
23 | 2.7V Dynamic differential pressure /mV | 200 | / | |||||||||||||||||||
24 | 30 Static pressure difference after minutes /mV | 10 | / | |||||||||||||||||||
25 | to ship | module SOC | 50% | / |
When using the battery module, it's important to keep the following precautions in mind:
Proper Handling: Handle the battery module with care to avoid physical damage or punctures that could lead to safety hazards.
Charging: Only use chargers recommended by the manufacturer to prevent overcharging, which can damage the cells and pose safety risks.
Discharging: Avoid deep discharges, as they can reduce the overall lifespan of the battery. Use within the specified voltage range.
Temperature: Operate the battery within the recommended temperature range. Extreme heat or cold can impact performance and safety.
Ventilation: Provide adequate ventilation when charging or discharging to prevent excessive heat buildup.
Battery Management System (BMS): Ensure the BMS is functioning properly to monitor cell balance, temperature, and prevent overcharging or over-discharging.
Physical Protection: Protect the battery from physical impacts, moisture, and exposure to flammable materials.
Storage: If storing the battery for an extended period, ensure it's at a partial charge (around 50%) and in a cool, dry place.
Compatibility: Use the battery module in systems designed to handle its specifications to prevent overloading or other compatibility issues.
Maintenance: Regularly inspect and maintain connections, wiring, and the BMS to ensure safe and reliable operation.
Authorized Service: Seek professional assistance from authorized technicians for any maintenance, repair, or modification.
Always refer to the manufacturer's guidelines and documentation for specific usage instructions and safety recommendations.