Item | PHES11.5kWhPV3 | |
Battery Type | LFP | |
Rated Voltage | 192V | |
Rated Capacity | 60Ah | |
Stored Energy | 11520Wh | |
Working Voltage Range | 150V~220V | |
Maximum Continuous Discharge Current | 60A | |
Standar Discharge Current | 30A | |
Maximum Continuous Charge Current | 60A | |
Standar Charge Current | 30A | |
Cycle Life | > 2000 @ 80% DoD | |
Environment | Charge Temperature | 0℃~50℃ |
Discharge Temperature | -20℃~50℃ | |
Storage Temperature | -20℃~50℃ | |
Humidity | <90% (no condensing) | |
Heat Emanation | Natural Cooling | |
Dimensions | W600xD600xH11457mm | |
Net Weight | 75kg | |
IP Grade | IP20 | |
Noise | < 40dB | |
Display | LCD | |
Communication | RS485 / CANBus |
Precautions
Safety First: Prioritize safety at all times. Follow manufacturer guidelines and local regulations for proper installation, usage, and maintenance.
Proper Ventilation: Ensure the battery is placed in a well-ventilated area to prevent overheating and promote optimal performance.
Temperature Control: Maintain a suitable operating temperature range to prevent excessive heat or cold from affecting battery life and performance.
Regular Inspection: Periodically inspect the battery for signs of damage, leakage, or corrosion. Address any issues promptly.
Charging Practices: Follow recommended charging practices to prevent overcharging or undercharging, which can impact battery health.
Load Management: Be mindful of the connected load's power requirements to avoid overloading the battery and compromising its backup capacity.
Maintenance Schedule: Adhere to a regular maintenance schedule, including checking voltage levels, cleaning terminals, and replacing aging batteries as needed.
Disposal: Dispose of old batteries responsibly, following local regulations for battery recycling and disposal.
Testing: Regularly test the battery and UPS system to ensure they function properly and provide the expected backup during power outages.
Backup Time Planning: Determine the required backup time for your devices and select a battery with sufficient capacity to meet those needs.
Compatibility: Ensure the chosen battery is compatible with your specific UPS model to guarantee seamless integration and optimal performance.
Documentation: Keep records of installation, maintenance, and any incidents related to the battery for future reference.
Remember, each UPS system and battery type may have unique considerations, so always refer to the manufacturer's guidelines and consult with professionals if needed.