Availability: | |
---|---|
215kw Outdoor Energy Storage Solution
HelithTech
Product Description
Product Introduction:
Helith Technology (Guangzhou) Co., Ltd. presents the Magna-C&I-215, a cutting-edge lithium battery solution tailored for commercial and industrial applications. Engineered to deliver dependable power and exceptional performance, this battery unit is designed to meet the demanding energy storage needs of modern businesses.
Product Specifications:
Rated Energy: 215 kWh @ 0.5C
Rated Power: Integrated 100 kW
Rated Output Voltage: 380 V AC
Cell Specification: 280 Ah
Cell Type: LFP (Lithium Iron Phosphate)
Cell Configuration: 1P 240S
Max Discharge Current: 173 A
Max Charge Current: 173 A
Charge Temperature: 0~45°C
Discharge Temperature: -20~50°C
Communication Method: CAN, 485
Thermal Management: Liquid-Cooled
Protection Level: IP55
Weight: 2800 kg
Dimensions: W1300 * D1300 * H2265 mm
Application Scenario: Commercial Low Voltage Connection
Key Advantages:
High Energy and Power Density: With a rated energy capacity of 215 kWh and integrated power of 100 kW, the Magna-C&I-215 offers impressive energy and power density, ensuring reliable performance in various commercial settings.
Robust and Durable Construction: Built with LFP cells in a 1P 240S configuration, this battery unit is designed for longevity and resilience, providing a stable energy storage solution for long-term use.
Efficient Thermal Management: Equipped with liquid cooling technology, the battery unit effectively manages heat dissipation, ensuring optimal performance even in challenging environmental conditions.
Advanced Communication and Integration: Featuring CAN and 485 communication methods, the Magna-C&I-215 facilitates seamless integration with other systems, allowing for efficient monitoring and control.
Versatile Application: Designed for commercial low-voltage connections, this battery unit is suitable for a wide range of applications, including renewable energy integration, peak shaving, and grid stabilization, offering flexibility and versatility to businesses.
Parameters
Parameter | Value |
Model | Magna-UTL-373 |
Product Category | DC Liquid-Cooled Outdoor Energy Storage Cabinet |
Rated Energy | 372.7 kWh @ 0.5C |
Rated Power | Recommended External 180 kW |
Rated Output Voltage | 900-1500 V DC |
Cell Specification | 280 Ah |
Cell Type | LFP (Lithium Iron Phosphate) |
Cell Configuration | 1P 416S |
Max Discharge Current | 173 A |
Max Charge Current | 173 A |
Charge Temperature | 0~45°C |
Discharge Temperature | -20~50°C |
Communication Method | CAN, 485 |
Thermal Management | Liquid-Cooled |
Protection Level | IP55 |
Weight | 3400 kg |
Dimensions | W1300 * D1300 * H2355 mm |
Application Scenario | Generation Side / Grid Side / User Side |
Precautions
Transportation Precautions:
Ensure the battery unit is securely packaged and protected from mechanical damage during transportation.
Follow all applicable regulations and guidelines for the transportation of lithium batteries, including proper labeling and documentation.
Avoid exposing the battery unit to extreme temperatures or humidity during transit, as it may affect performance and safety.
Operational Precautions:
Install the battery unit in a well-ventilated and temperature-controlled environment according to the manufacturer's guidelines.
Monitor the temperature and operating conditions regularly to prevent overheating or overcharging.
Ensure proper ventilation to dissipate heat generated during operation, especially in enclosed spaces.
Follow recommended charging and discharging parameters to maintain optimal performance and prolong battery life.
Regularly inspect for any signs of damage or deterioration and address them promptly to prevent potential hazards.
Maintenance Precautions:
Perform routine maintenance checks as recommended by the manufacturer to ensure the battery unit's continued reliability and safety.
Keep the battery unit clean and free from dust or debris accumulation to prevent potential electrical or thermal issues.
Inspect and tighten all connections periodically to prevent loose connections, which can lead to electrical arcing or short circuits.
Monitor the electrolyte levels and refill as necessary, following proper safety procedures and guidelines.
Emergency Response:
In case of any unusual behavior or malfunction during operation, immediately disconnect the battery unit from the power source and cease operation.
Evacuate the area and follow established safety protocols to minimize the risk of injury or damage.
Contact trained personnel or emergency services for assistance and follow their instructions carefully.
Do not attempt to disassemble or repair the battery unit yourself, as it may pose a risk of electric shock or chemical exposure.
Provide relevant information, including the model and specifications of the battery unit, to facilitate prompt and effective response measures.
content is empty!